Duct Spacers · Size 2 inch (50 mm)

2" Duct Spacers (50 mm)

A 2" duct spacer holds 2" (50 mm) conduit on a precise grid while a duct bank is assembled, poured, and backfilled — base spacers set the bottom row, intermediate spacers stack the rows above.

Innovative Plastics base and intermediate two-piece duct spacers

Innovative Plastics molds 2" duct spacers in both base and intermediate styles from high-impact polymer. The two halves interlock vertically and horizontally, so a 2" duct bank locks together as one rigid grid with no banding, tie wire, or field measuring between conduits.

The 2" size covers the smaller primary and secondary conduit common on electrical, broadband, and fiber duct banks, and is offered in three separations — 1.5", 2", and 3" — to match the gap called out on your drawings. Base and intermediate 2" spacers use the 40xx / 41xx part numbers below.

Need a different trade size? The same interlocking system runs from 2" through 8" on the full duct spacers family page. For step-by-step assembly, see installing conduit duct spacers and duct bank spacing.

Specifications

2 inch (50 mm) sizes & part numbers

Price: $1.05–$1.20 each, effective 2026-07-23. Minimum order one case; volume & distributor pricing available.

Base Duct Spacers
Product image Product Number Trade Size (in) Trade Size (mm) Case Qty Price (USD) Order (cases)
4020-15 product 4020-15 2.00 x 1.50 50 x 40 450 $1.19
4020-20 product 4020-20 2.00 x 2.00 50 x 50 325 $1.18
4020-30 product 4020-30 2.00 x 3.00 50 x 80 300 $1.20
Intermediate Duct Spacers
Product image Product Number Trade Size (in) Trade Size (mm) Case Qty Price (USD) Order (cases)
4120-15 product 4120-15 2.00 x 1.50 50 x 40 500 $1.07
4120-20 product 4120-20 2.00 x 2.00 50 x 50 325 $1.10
4120-30 product 4120-30 2.00 x 3.00 50 x 80 275 $1.05

Made in Texas, USA · ships across the US. Looking for other sizes? See the full Base & Intermediate range.

FAQ

Frequently asked questions

What separations does the 2" duct spacer come in?
Three separations — 1.5" (40 mm), 2" (50 mm), and 3" (80 mm) — in both base (40xx) and intermediate (41xx) styles. Match the separation to the conduit gap on your project drawings.
Do 2" duct spacers need banding?
No. The two-piece design interlocks vertically and horizontally, so the bank stays aligned under worker weight and through the pour or backfill with no banding or tie wire required.
Are base and intermediate 2" spacers sold separately?
Yes. Base spacers sit on the trench floor as the bottom course; intermediate spacers stack above them. Order the mix your bank height needs — both ship by the case.